Flip the automatic door control switch on the stanley automatic door operator header box to hold open confirm the door operator opens each time you do that.
Stanley automatic doors stuck open.
Stanley automatic sliding door timing belt for bi parts and single slides.
When you turn on the power to the automatic doors do the automatic sliding doors open and then suddenly stop.
Secure door to its hanger by pushing door panels in from the outside.
Today stanley access technologies proudly manufactures installs and services sliding swinging folding transit metro and revolving door systems as well as.
You will find our automatic sliding doors throughout north america and europe in a wide variety of locations including.
Le low energy knowing act doors open when an activation device is engaged such as a push.
Stanley automatic sliding doors are by far the most popular door system in america.
For knowing act push plate operators.
If the door is stuck open make sure it is not in the hold.
What makes this door system unique is the use of the bearing drive block rod and cable as most automatic sliding door systems are comprised of a rubber timing belt which moves along the dc motor pulley.
If door does not open close turn power off for 15 seconds then switch on fe full energy doors open as soon as the motion sensor detects motion.
Check to confirm that the power switch is in the on position.
Doors are stuck in the same position and will not move.
We also perform repairs and maintenance on all brands of automated doors.
Do not use any kind of grease including lithium grease as it causes dirt to get stuck to the wheel.
The bearing drive block then slides along the rod making the doors open.
Our stanley automatic door is squeeking.
Or vice versa the door will open and close in the opposite direction.
If the door is stuck open make sure it is not.
Check the battery on the transmitter if door is controlled remotely.
Overhead interior exterior sensor zones are clear and there are no items in the pathway of door for the following steps turn power off.
On stanley automatic doors the power switch is the illuminated red switch typically found on the side of the door system jamb tube or on the underside of the header.
I used wd40 and it did not help.
Check to make sure all transmitters have a fully energized 9 volt battery.
If the door does not open close turn power off for 15 seconds then switch on.
If this is the case you know the problem is in the wireless handicap push button radio controls.
Stanley access technologies manufactures state of the art automatic slide doors for industrial commercial healthcare and retail use.